Each force-controlled joint module measures the moment carried by the joint shaft inside the joint. It returns that reading to the controller as a signal the loop can act on, so the axis regulates the force it applies, not only the position it reaches. Its sensing element, the drive, the encoder interface, and the reduction stage share one housing, one cable run, and one calibration route.
A position-commanded machine reports the angle it has reached and, indirectly, the current its motor draws. Neither number states how much torque the load applies to a joint. A stiff position loop is built to suppress exactly the position error that would otherwise encode that force. Force control therefore needs a separate measurement at a known point in the drivetrain, inside a loop fast enough to act before the contact is over. The roles of motor, reducer, drive, and encoder are covered in our guide to robot joint actuators.
The observation point decides what the loop can resolve. An estimate from motor current sits upstream of the reduction stage, so the friction, hysteresis, and lost motion of the transmission lie between the reported effort and the load that resists motion. A strain-based element on the output flange, or on a dedicated elastic member in the load path, sits downstream of the reducer, so its output follows the external contact, not the motor effort. A wrist sensor reports the resultant at the tool, but no arithmetic recovers the share carried by one axis.
Inside a force-controlled joint module, the element is instrumented at the joint, and its signal is acquired in the same enclosure as the drive and the position feedback. That reading stays inside the joint, with no analog voltage routed through a cabinet. Sampling, filtering, and loop execution that turn it into a torque command stay on a short path.
Two figures decide whether the signal is usable: resolution, the smallest change in contact force distinguishable from the noise floor, and response, the time the loop takes to act. Any contact below that floor passes undetected, and a loop that acts after the impact has finished does nothing for safety.
Placing the measurement and the loop in the actuator unit is a structural decision, and its consequences appear in three places.
Communication protocols depend on the voltage series: the 48 V DC low-voltage joint modules support CANopen, CAN FD, EtherCAT, and Modbus; the 220 V AC high-voltage joint modules support BiSS-C and TAMAGAWA. Confirm the exact encoder and communication configuration for the selected model.
The force loop does not act on a rigid body. Strain wave gearing is compliant, and joint torsional stiffness sets the resonance between the reflected motor inertia and the load mass, so it bounds the bandwidth a force loop can reach. Hysteresis and lost motion act as a deadband at small amplitude, which makes small contact forces the hardest to hold and places stiffness and repeatability inside the force control budget, not beside it. Because the force loop runs in cascade with the position loops, the inner loops have to be faster than the behavior the outer loop controls.
Joint-level sensing puts an instrument on every axis, not one at the wrist. Each unit has to be calibrated and compensated for temperature drift, and each needs a cable that survives the duty it sees. One that integrates the drive answers that directly. Its enclosure carries IP67 protection and class F motor insulation rated at 155 °C. T-type joints and selected precision bearings receive a black oxide treatment whose dense oxide film raises corrosion resistance. On the low-voltage side, the drive is built in at 48 V DC, which makes distributed sensing practical on a machine with many axes. Its range and interfaces are listed on the DC low voltage joint modules page.

Force control is added to the architecture a joint module already carries, not substituted for it. Its integrated drive regulates motor current, which supplies the effort command the outer loops modulate. A motor-side encoder closes the position loop at a high rate but reports the motor shaft, so error introduced by the reducer remains in the quantity the loop acts on.
Dual-loop position control closes a second loop on the output side, where the flange angle is read directly, so gear error and series backlash stay outside the reported position. An absolute encoder retains position and multi-turn count through a power loss, so an axis needs no referencing move after a restart. Its torque loop observes the same mechanical point: the element and the output-side encoder both act downstream of the reducer.
| Layer | Quantity It Closes On | Where It Is Measured | What It Contributes to Force Control |
|---|---|---|---|
| Current loop | Motor winding current | Sensing in the drive | Supplies the effort the outer loops modulate |
| Position loop, motor side | Motor shaft angle | Motor-side encoder | Holds the commanded trajectory |
| Position loop, output side | Output flange angle | Absolute encoder on the joint shaft | Removes gear error and series backlash from the reported position |
| Joint torque loop | Moment about the joint axis | Element inside the joint | Regulates contact force, detects collisions, follows a hand-guided move |
| Process force loop | Resultant at the tool | Wrist force and torque sensor | Sets the quantity a finishing process is defined by |
Each layer becomes progressively slower and closer to the load. A comparison with a separate motor, reducer, drive, and sensor arrangement is treated in the actuator robot basics background, and the layered architecture that follows is described under intelligent robotic joints.
In insertion, polishing, grinding, deburring, and compliant gripping, the acceptance criterion is the contact force, not the position reached. A force that is too high damages the workpiece, and one that is too low leaves the task unfinished. A wrist sensor can regulate the resultant. Where the operation is distributed along the arm, joint-level data adds which axis carries how much of the load and whether it is offset. Each axis can then close its own torque loop. High-voltage modules are aimed at heavy-duty work on large industrial arms, while low-voltage modules serve the lighter, more distributed end of it.
Drag teaching compresses a trajectory that would otherwise be taught point by point. The operator leads the arm along the path by hand while the controller records the motion, so a path that would need many taught points is captured in one pass. What the module contributes is resolution.
The element must see the small external torque an operator applies through the friction, hysteresis, and gravity load already in the train, or the arm feels heavy and the recorded path loses accuracy. The same reading serves safety, since the joint watches torque change and recognizes the transient that an unexpected contact superimposes on the normal gravity, inertial, and process loads. Faster sensing permits a tighter limit, and that is what lets a person and an arm work close together without giving up speed.

Selection starts on the load side. Rated torque for each size is defined at an input speed of 2,000 rpm, so an axis has to satisfy average load torque against the permissible average load torque figure first. Average and maximum input speed are checked next. For a unit with a built-in cross-roller bearing, maximum moment load, bearing life, and static safety factor are checked at the mounting the arm uses. Backlash is chosen by series, at ≤60, ≤30, or ≤20 arcseconds.
Force-side checks come next. Measuring range has to cover the largest transient the joint will meet in service, including the collision it is expected to detect. Calibration and temperature compensation have to be defined for each unit. Bus selection has to deliver a cycle short enough for the loop rate the process requires, from the protocols carried across the range.
| Item | Published Coverage |
|---|---|
| Integration | Force-controlled joint modules with real-time torque feedback for drag teaching, collision detection, and torque control |
| Outside diameter | 40 mm to 190 mm, continuous across the range |
| Supply forms | 48 V DC with built-in servo drive for distributed control; 220 V AC with large hollow shaft support for high-power arms |
| Models | DC 48 V: L40I, L52I, L60I, L70I, L80I, L90I, L110I, L142I, L170I, L190I; AC 220 V: M70, M80, M90, M110, M142, M170, M190 |
| Payload classes | 3 kg to 20 kg |
| Positioning accuracy | ±15 arcseconds |
| Design life | 10,000 to 15,000 hours |
| Feedback and communication | Absolute encoder retaining position and multi-turn count through a power loss; dual-loop position control. Communication: DC 48 V supports CANopen, CAN FD, EtherCAT, and Modbus; AC 220 V supports BiSS-C and TAMAGAWA. |
| Protection and insulation | IP67 enclosure; class F motor insulation at 155 °C |
| Item to Settle at Commissioning | Why It Matters | What Has to Be Decided |
|---|---|---|
| Zero offset and temperature compensation | Every element reading is referenced to a zero taken in one condition | Whether the zero is set with the arm unloaded, and how compensation is applied with temperature |
| Filtering against loop rate | Filtering removes noise but adds phase lag | The cutoff that keeps the loop stable while retaining resolution enough to see a small contact force |
| Bus protocol and cycle | Sampling, transmission, and execution must fit one short cycle | Which protocol the controller runs, and whether the -C or -E version is specified |
That argument for placing force control in the actuator goes beyond adding a sensor to a joint. A joint designed around the measurement removes the parts of the chain between the load and the loop. Its element sits downstream of the reducer, where transmission friction and hysteresis no longer mask the external contact. Acquisition, filtering, and loop execution sit inside the housing that carries the drive and the encoder interface. That delay between measurement and command then belongs to the module, not to the cabinet layout.
The same integration settles what a specifier has to do. Load-side checks come first, with average load torque against the permissible figure and, for a unit with a built-in cross-roller bearing, the moment load, bearing life, and static safety factor. Force-side checks then add the measuring range of the element, the calibration and temperature compensation route, and a protocol whose cycle fits the loop rate the process needs. One family covering 40 mm to 190 mm outside diameter lets a collaborative arm, an assembly head, and a finishing tool be specified from one interface. Low-voltage modules run their own drive on 48 V DC, and high-voltage modules offer large hollow shafts on 220 V AC.
Because the measurement stays inside the joint, the data a force loop needs is present at the axis where the force is generated. That is the difference between following a trajectory and controlling the contact made along it. Those duties that follow, from an arm guided by hand to a process that fails when the contact force leaves its window, are set out under robotics applications. The continuous size spectrum of the joint modules family lets one integration decision be repeated on every axis.
Contact our motion control engineers for custom torque sensor range definitions, real-time EtherCAT cycle integration, and humanoid actuator prototypes.