Selecting Joints for an Eight-Axis Machine in One Pass

        An eight-axis machine rarely fails on the strength of any single joint; it fails on the matching work between them. Joint module selection at machine level means assigning a drive to every axis position from one envelope, one interface system, and one set of acceptance checks. That assignment has to be… Continue reading Selecting Joints for an Eight-Axis Machine in One Pass

Date September 12, 2026

Selecting Joints for an Eight-Axis Machine in One Pass
Laifual Drive > Selecting Joints for an Eight-Axis Machine in One Pass

An eight-axis machine rarely fails on the strength of any single joint; it fails on the matching work between them. Joint module selection at machine level means assigning a drive to every axis position from one envelope, one interface system, and one set of acceptance checks. That assignment has to be completed while the structure is still open to revision.

The axis count sets the scale. A collaborative arm carries six or seven rotary joints and a humanoid platform can exceed twenty, so eight axes sit in the middle of that range.

Laifual Drive joint modules span outside diameters from 40 mm to 190 mm. The DC low-voltage series operates on 48 V and includes L40I, L52I, L60I, L70I, L80I, L90I, L110I, L142I, L170I, and L190I. It supports CANopen, CAN FD, EtherCAT, and Modbus. The AC high-voltage series operates on 220 V and includes M70, M80, M90, M110, M142, M170, and M190. It supports BiSS-C and TAMAGAWA. Confirm torque, speed, mounting, encoder, and communication requirements for each axis before final model selection.

Selecting Joints for an Eight-Axis Machine in One Pass

Why Separate Sourcing Breaks Down Across Eight Axes

Multi-axis difficulty is not the sum of single-axis difficulty. Each position has its own load case, yet all positions share one structure, one control cabinet, and one qualification record. That combination produces three constraints no single unit performance figure addresses.

The Envelope Constraint Is Rigid

Once the structure is released, the volume and mounting face at each joint are fixed. If the catalog lacks the frame class that fits an axis, the structure gets redrawn around an available size. A redraw at axis three then invalidates the load paths assumed at axes one and two. Envelope is the one requirement that cannot be compensated downstream, and the robot joint types a machine is built from do not loosen it.

The Interface Constraint Is Global

Mechanical mounting, electrical supply, feedback format, and bus protocol all have to agree. One mismatch adds an adaptation layer at the controller. That cost scales with the number of distinct sources, not the number of joints: eight axes from three suppliers mean three cable sets and three commissioning procedures.

The Verification Constraint Repeats Itself

Every distinct model goes through incoming inspection, single-unit test, machine-level integration, and aging separately. Four frame classes therefore generate four verification records, and eight unrelated sources generate eight.

The Axis List and Duty Table That Precede Any Model Number

Two documents come before the first catalog lookup. An axis list names each position and its role in the kinematic chain, which fixes the load class before a single number is computed. A duty table then records what that position actually does across a complete cycle.

Recorded per Axis Unit Where It Comes From What It Decides
Available envelope: outside diameter limit and mounting face mm Released structure drawing Which frame classes remain candidates
Carried mass: link and payload seen by that axis kg Kinematic chain and end effector Payload class band, 3 kg to 20 kg
Average output torque over the cycle N·m Gravity, acceleration, and process force terms The average load torque check
Peak output torque and its duration N·m, s Worst-case motion Thermal and structural margin
Average and maximum output speed r/min Motion profile The input speed checks Ni av and Ni max
External moment load at the output flange N·m Overhung load or tilting case The moment load check on unit-type joints
Required accuracy and backlash grade arcsec Process tolerance and repeatability Series and grade: ≤60, ≤30, or ≤20
Routing need through the axis center bore Cables, air lines, vacuum lines Hollow-shaft or solid-shaft version
Duty class and running hours per year h Production plan Design life of 10,000 to 15,000 hours

Two properties matter more than the arithmetic. Rows three and five are averages over the whole cycle, holding periods included, not values from the fastest move, since a joint holding a position against gravity is still loaded. Row six applies only to unit-type joints with an integrated cross-roller bearing, and it is a structural limit the gear rating does not cover. What a module contributes at each of those rows is set out in what a joint module is.

Three Acceptance Checks Applied to Every Axis

A frame that passes one check can fail another; the three checks are separate limits.

Average Load Torque and the Rated Point

Rated torque in the Laifual Drive catalogs is the permissible continuous load torque at a rated input speed of 2,000 rpm, and a torque figure quoted without that reference cannot be compared across suppliers. For an axis on a repeating production cycle, rated torque is not the governing value. What controls the choice is the time-weighted average load torque Tav over the full cycle, compared against the permissible average load torque of the candidate frame at the intended ratio. A unit chosen on peak torque can pass that peak and still run hot everywhere else in the cycle.

The δ tooth profile supports that margin from the tooth side. A multi-segment continuously variable curvature arc replaces the conventional double circular arc. That arc raises load capacity by 15% to 30%, cuts temperature rise by 8 to 10 °C, and reduces the tooth flank area exposed to fatigue pitting by more than 30%.

Input Speed Limits, Ni av and Ni max

Average input speed Ni av is validated against the duty cycle, and maximum input speed Ni max against the transient peak. Both are limits in their own right. An axis can be acceptable on average and unacceptable if one fast repositioning move exceeds Ni max. Speed and frame choice interact through the ratio, since a higher reduction lowers the input speed needed for a given output speed. It also raises the torque the motor must supply, so both checks are read together.

Moment Load and Bearing Capacity on Unit-Type Joints

For a unit-type module with an integrated cross-roller bearing, three structural criteria are added. They are maximum moment load at the output flange, bearing life for the actual moment and axial load profile, and the static safety factor against the specified worst case. Those checks stay independent of the gear rating. On a base rotation or positioner tilt axis, they normally decide the frame.

Backlash grade follows the accuracy requirement, not the load, at ≤60, ≤30, or ≤20 arcseconds by series. Read it against the ±15 arcsecond positioning accuracy of the family, so a precision axis does not inherit the widest grade because it shares a frame size with a heavy axis.

Three Acceptance Checks Applied to Every Axis

One Spectrum and Four Load Bands in an Eight-Axis Example

The machine below is a six-axis collaborative arm mounted on a two-axis positioner, eight rotary joints in total. Frame bands are starting points from the size correspondence published for the joint modules spectrum. In that spectrum, a 40 mm module outside diameter corresponds to roughly reducer size 8 and 170 mm to roughly size 40. The band column names the class to check first. The last column names the deciding check.

Axis Position Load Class Supply Line Starting Frame Band Check That Usually Governs
A1 base rotation Heaviest in the chain AC 220 V M170 class, 170 mm to 190 mm Moment load, bearing life, static safety factor
A2 shoulder High torque AC 220 V M142 to M170, 142 mm to 170 mm Average load torque Tav
A3 elbow High torque, moderate speed AC 220 V M110 to M142, 110 mm to 142 mm Tav and Ni av together
A4 wrist roll Medium load, short moves DC 48 V L90I to L110I, 90 mm to 110 mm Reflected inertia and mass
A5 wrist pitch Light load DC 48 V L80I to L90I, 80 mm to 90 mm Backlash grade against ±15 arcsec
A6 tool flange roll Lightest, fastest DC 48 V L70I to L80I, 70 mm to 80 mm Inertia and Ni max, ≤20 arcsec grade
A7 positioner tilt Heavy static load, low speed AC 220 V M170 class, 170 mm to 190 mm Moment load and static safety factor
A8 positioner rotation Medium, continuous duty AC 220 V M142 to M170 hollow, 142 mm to 170 mm Ni av under continuous duty, IP67 sealing

Two patterns come from physics, not the catalog: mass and inertia dominate at the distal end, where a smaller frame with lower rotor inertia reduces the torque every proximal axis must supply. Torque and moment capacity dominate at the base end, where the frame is set by structure and load path, not motor speed. The result is four frame bands instead of eight oversized units or eight unrelated models.

The DC Low-Voltage Line for Distributed Axes

The 48 V DC low-voltage family integrates the servo drive into the joint module. Available models are L40I, L52I, L60I, L70I, L80I, L90I, L110I, L142I, L170I, and L190I, with support for CANopen, CAN FD, EtherCAT, and Modbus. This architecture can reduce long motor and feedback cable runs and cabinet space on distributed axes; the exact configuration should be verified against the selected model.

The AC High-Voltage Line for High-Power Axes

The 220 V AC high-voltage family includes M70, M80, M90, M110, M142, M170, and M190. It features a compact design, high precision, and a large hollow structure, helping simplify model selection, system design, and manufacturing. The supported communication protocols are BiSS-C and TAMAGAWA. Verify hollow-shaft dimensions and the required interface on the AC high voltage joint modules page and in our strain wave gear series catalog.

Interface and Protocol Uniformity Across the Whole Machine

Fixing eight frame bands is half the exercise. The interface layer is the other half, because that is what turns eight selections into one table instead of eight supplier relationships.

Interface Layer Constant Across the Eight Axes Varies by Axis Position
Mounting interface Mounting face convention and flange geometry within a line Flange size follows the frame band
Electrical architecture 48 V DC or 220 V AC chosen per group, not per axis Drive power stage, brake, version
Feedback Absolute encoder retaining position and multi-turn count through a power loss, dual-loop control Resolution class and feedback format
Communication DC 48 V: CANopen, CAN FD, EtherCAT, Modbus; AC 220 V: BiSS-C, TAMAGAWA Protocol support depends on the selected voltage series
Protection and environment IP67 enclosure across the module range Sealing at the input fixed end, at the output end, and in the flexspline cavity

The consequence is architectural. When eight axes come from one spectrum, the controller keeps one motion library, one bus configuration, and one set of diagnostics, and the hours spent on adapters move to load calculations. Selecting in one pass does not mean every axis carries the highest rating available. It means every axis position has a matching band inside one system, and the robotic joint module overview makes that argument at the actuator level.

Specifying a Multi-Axis Machine in One Pass

An eight-axis machine is specified from one axis list, one duty table, and three acceptance checks applied to every row. Frame bands come from a continuous spectrum of 40 mm to 190 mm outside diameter. The time-weighted average load torque check governs the working axes, and the speed limits Ni av and Ni max govern the fast repositioning moves. Moment load, bearing life, and static safety factor checks then govern the base and positioner axes.

Because the checks run while the structure is still open, one spectrum covers both the light distal axes and the loaded base axes without a change of supplier or interface. Joint module selection across a multi-axis machine therefore reduces to one table, one interface system, and one set of calculations made before the first drawing is released.

Configure Your Multi-Axis Robotic Drivetrain

Contact our kinematic engineering team for integrated eight-axis duty cycle mapping, CAD envelope verification, and unified bus protocol sizing.